Abstract
The aim of the study was to evaluate the reliability and durability of alumina-on-alumina ceramic in comparison to metal-on-highly cross-linked polyethylene (CoCr/HXLPE) bearing couples. This prospective randomised study involved 150 patients (157 hips). All patients (mean age: 54.7 years) obtained an identical fibre metal midcoat femoral stem and fibre metal-coated acetabular shell. In 78 patients (82 hips) we used alumina, while in 72 patients (75 hips) metal-polyethylene bearing couples were used. During a mean 50.4-month follow-up period (51 ± 8 alumina and 50 ± 8.9 metal-polyethylene) no statistically significant changes in clinical and radiographic parameters were noted between the two groups. There was no ceramic breakage and no need for revision surgery due to the ceramic liner. The alumina bearing couples proved to be as reliable as CoCr/HXLPE.
Similar content being viewed by others
References
Bragdon C, O’Connor D, Lowenstein J, Jasty M, Syniuta W (1996) The importance of multidirection motion on the wear of polyethylene. Proc Inst Mech Eng H 210:157–165
Bragdon C, Jasty M, Muratoglu O, O’Connor D, Harris W (2003) Third-body wear of highly cross-linked polyethylene in a hip simulator. J Arthroplasty 18:553–561
Callaway G, Flynn W, Ranawat C, Sculco T (1995) Fracture of the femoral head after ceramic-on-polyethylene total hip arthroplasty. J Arthroplasty 10:855–859
Capello W, D’Antonio J, Feinberg J, Manley M, Naughton M (2008) Ceramic-on-ceramic total hip arthroplasty: update. J Arthroplasty 23(7 Suppl):39–43
Clarke I (1992) Role of ceramic implants. Design and clinical success with total hip prosthetic ceramic-to-ceramic bearings. Clin Orthop Relat Res 282:19–30
D’Antonio J, Capello W, Manley M (1996) Remodeling of bone around hydroxyapatite-coated femoral stems. J Bone Joint Surg Am 78:1226–1234
D’Antonio J, Capello W, Manley M, Bierbaum B (2002) New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty. J Arthroplasty 17:390–397
DeLee J, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32
Bowsher J, Williams P, Clarke I, Green D, Donaldson T (2008) “Severe” wear challenge to 36 mm mechanically enhanced highly crosslinked polyethylene hip liners. J Biomed Mater Res B Appl Biomater 86:253–63
Engh C, Massin P, Suthers K (1990) Roentgenographic assessment of the biologic fixation of porous–surfaced femoral components. Clin Orthop Relat Res 257:107–128
Gruen T, McNeice G, Amstutz H (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27
Harris W (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51:737–755
Klisic P, Rakic D, Pajic D, Parezanovic V (1990) Prevention, care and screening of hips of newborn infants (in French). Acta Orthop Belg 56:95–102
Malchau H, Henberts P, Ahnfelt L (1993) Prognosis of total hip replacement in Sweden. Follow-up of 92,675 operations performed 1978–1990. Acta Orthop Scand 64:497–506
Malchau H, Garellick G, Eisler T, Kärrholm J, Herberts P (2005) Presidential guest address: the Swedish Hip Registry: increasing the sensitivity by patient outcome data. Clin Orthop Relat Res 441:19–29
McKellop H, Shen F, DiMaio W, Lancaster JG (1999) Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls. Clin Orthop Relat Res 369:73–82
Mu Z, Tian J, Wu T, Yang J, Pei F (2009) A systematic review of radiological outcomes of highly cross-linked polyethylene versus conventional polyethylene in total hip arthroplasty. Int Orthop 33:599–604
Ramamurti B, Bragdon C, O’Connor D, Lowenstein J, Jasty M, Estok D, Harris W (1996) Loci of movement of selected points on the femoral head during normal gait. Three-dimensional computer simulation. J Arthroplasty 11:845–852
Ramamurti B, Estok D, Jasty M, Harris W (1998) Analysis of the kinematics of different hip simulators used to study wear of candidate materials for the articulation of total hip arthroplasties. J Orthop Res 16:365–369
Sakoda H, Voice A, McEwan M, Isaak G, Hardaker C, Wroblewski B, Fisher J (2001) A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene. J Arthroplasty 16:1018–1023
Taylor S, Manley MT, Sutton K (2007) The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings. J Arthroplasty 22(7 Suppl 3):47–51
Vukasinović Z, Vucetić C, Cobeljić G, Bascarević Z, Slavković N (2006) Developmental dislocation of the hip is still important problem—therapeutic guidelines (in Serbian). Acta Chir Iugosl 53:17–19
Vukasinović Z, Zivković Z, Vucetić C (2009) Developmental hip dysplasia in adolescence (in Serbian). Srp Arh Celok Lek 137:440–443
Willmann G (2000) Ceramic femoral head retrieval data. Clin Orthop Relat Res 379:22–28
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Bascarevic, Z., Vukasinovic, Z., Slavkovic, N. et al. Alumina-on-alumina ceramic versus metal-on-highly cross-linked polyethylene bearings in total hip arthroplasty: a comparative study. International Orthopaedics (SICOT) 34, 1129–1135 (2010). https://doi.org/10.1007/s00264-009-0899-6
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00264-009-0899-6