- S P Harding, consultant ophthalmic surgeona,
- D M Broadbent, research fellowa,
- C Neoh, registrar in ophthalmologya,
- M C White, consultant physician+b,
- J Vora, consultant physicianb
- aSt Paul's Eye Unit, Royal Liverpool University Hospital, Liverpool L7 8XP
- bDepartment of Endocrinology and Diabetes, Royal Liverpool University Hospital
- Correspondence to: Mr. Harding.+Michael White died on 13 August 1995.
Abstrac
Objective: To evaluate different methods for community based screening for sight threatening diabetic eye disease.
Design: Prospective study.
Setting: Mobile screening unit visiting inner city community clinics; hospital assessment clinic (tertiary centre).
Subjects: 395 diabetic patients registered with four general practices in an inner city location.
Interventions: Community based photography with mydriasis and direct ophthalmoscopy through dilated pupils by an experienced ophthalmologist, both compared with reference standard of slit lamp biomicroscopy by a consultant specialist in medical retinal disease.
Main outcome measures: Sensitivity and specificity of screening method and prevalence of sight threatening diabetic eye disease (moderate preproliferative retinopathy, circinate maculopathy, exudate within 1 disc diameter of fixation, other diabetes related eye disease).
Results: 358 subjects underwent photography, 326 attended hospital clinic for ophthalmoscopy, and six were ungradable on photographs and biomicroscopy, leaving 320 for analysis. Of these 295 (91%) attended clinic within four months of photography. Sensitivity of detection of eye disease by photography was 89% (95% confidence interval 80% to 98%), significantly better than for direct ophthalmoscopy (65% (51% to 79%)). Analysis of patients with false negative results indicated possible improvement of photographic sensitivity to 93% by addition of stereoscopic macular pair photographs. Specificity of detection of sight threatening eye disease was 86% (82% to 90%) for photography and 97% (95% to 99%) for direct ophthalmoscopy.
Conclusions: Since high sensitivity is essential for an effective screening programme, a photographic method should be considered as preferred option in national, community based screening programmes. Even in the hands of an experienced ophthalmologist, direct ophthalmoscopy is limited by weaknesses inherent to the instrument.
Footnotes
-
Funding The work was supported by grants from the British Diabetic Association and Liverpool Health Authority.
-
Conflict of interest None.
CiteULike
Connotea
Del.icio.us
Digg
Facebook
Mendeley
Reddit
Technorati
Twitter
Stumbleupon
Rapid responses
Latest Responses
Re: Venous thrombosis in users of non-oral hormonal contraception: follow-up study, Denmark 2001-10
Published 16 May 2012
Re: Outcomes of elective induction of labour compared with expectant management: population based study
Published 16 May 2012
Re: Outcomes of elective induction of labour compared with expectant management: population based study
Published 16 May 2012
Re: Why the US healthcare system is failing, and what might rescue it
Published 16 May 2012
Re: Risk of cardiovascular serious adverse events associated with varenicline use for tobacco cessation: systematic review and meta-analysis
Published 16 May 2012
Most responses
Is spending on proton beam therapy for cancer going too far, too fast? (11 responses)
Published 17 Apr 2012 - 23:32
What are the benefits of an early diagnosis? (8 responses)
Published 18 Apr 2012
The psychiatric oligarchs who medicalise normality (8 responses)
Published 2 May 2012
Are doctors justified in taking industrial action in defence of their pensions? No (8 responses)
Published 8 May 2012 - 12:21
Are doctors justified in taking industrial action in defence of their pensions? Yes (8 responses)
Published 8 May 2012 - 12:21