Jump to: Page Content, Site Navigation, Site Search,
You are seeing this message because your web browser does not support basic web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.
Published 23 January 2009, doi:10.1136/bmj.a3112
Cite this as: BMJ 2009;338:a3112
Ole M Ekeberg, research fellow 1, Erik Bautz-Holter, professor 1, Einar K Tveitå, research fellow 1, Niels G Juel, consultant physician 1, Synnøve Kvalheim, consultant physician 1, Jens I Brox, consultant physician2,3
1 Department of Physical Medicine and Rehabilitation, Ullevål University Hospital and Medical Faculty, University of Oslo, 0407 Oslo, Norway, 2 Department of Orthopaedics, Back Surgery and Physical Medicine and Rehabilitation Section, Rikshospitalet University Hospital and Medical Faculty, University of Oslo, 0027 Oslo, 3 Unifob Health, University of Bergen, Bergen, Norway
Correspondence to: O M Ekeberg o.m.ekeberg{at}medisin.uio.no
Design Double blind randomised clinical trial.
Setting Outpatient clinic of a physical medicine and rehabilitation department in Oslo, Norway.
Patients 106 patients with rotator cuff disease lasting at least three months.
Interventions Ultrasound guided corticosteroid and lidocaine injection in the subacromial bursa and lidocaine injection in the gluteal region (local group); corticosteroid and lidocaine injection in the gluteal region and ultrasound guided lidocaine injection in the subacromial bursa (systemic group).
Main outcome measures Difference in improvement in the overall shoulder pain and disability index score after six weeks.
Results Six weeks after the intervention, the mean difference in improvement in overall shoulder pain and disability index score between the local group and the systemic group was –5.2 (95% confidence interval –13.9 to 3.5); it was –4.1 (–12.3 to 4.1, P=0.32) after adjustment for baseline score. A small but statistically significant difference in improvement between groups occurred in favour of the local group for two secondary outcome measures: the Western Ontario rotator cuff index (8.1, 0.7 to 15.6) and change in main complaint (2.0, 0 to 4).
Conclusions No important differences in short term outcomes were found between local ultrasound guided corticosteroid injection and systemic corticosteroid injection in rotator cuff disease.
Trial registration Clinical trials NCT00640575 [ClinicalTrials.gov] .
Non-operative treatment for rotator cuff disease primarily consists of active physiotherapy, which may be supplemented with non-steroidal anti-inflammatory drugs, steroid injections, and electrotherapy.3 Active physiotherapy has been reported to be superior to placebo and equivalent to surgery at long term follow-up.7 8 Despite extensive research, evidence for the effectiveness of steroid injections for rotator cuff disease is unconvincing. Conclusions of systematic reviews and meta-analyses are inconsistent and hampered by small sample sizes, variable methodological quality, and heterogeneity of the included studies.9 10 11
Corticosteroids are potent anti-inflammatory and pain modulating drugs with both systemic and local effects. The precise mechanism of local corticosteroid injections is not well understood. Possible therapeutic mechanisms include anti-inflammatory effects, relaxation of reflex muscle spasm, influence of local tissue metabolism, pain relief, mechanical improvement, and placebo effect.12
Thirty per cent to 80% of subacromial injections are reported to reach the subacromial bursa or the subacromial space when a blind injection technique is used.13 High frequency ultrasonography is a safe, accurate, readily available technique for guiding musculoskeletal aspiration and infiltration that ensures correct placement of the needle and delivery of the drug. Some studies have reported better short term improvement in patients when the injection has been placed accurately into an anatomical site or in the subacromial bursa.14 15 Valtonen reported that gluteal and subacromial corticosteroid injections significantly, and equally, improved supraspinatus tendonitis compared with placebo.16 Recently, two small randomised trials reported that ultrasonographically guided injections were significantly more effective than blind injections for short term pain relief and improved function.17 18 The participants were not blinded for treatment group in these two studies, which raises the possibility of a bias favouring ultrasound guided injections.
To investigate the importance of placement of corticosteroid injections in patients with rotator cuff disease, we did a randomised controlled study comparing the effectiveness of a systemic corticosteroid injection in the gluteal region with an ultrasound guided injection in the subacromial bursa in patients with rotator cuff disease. We used a double blind design.
We excluded patients who had symptomatic acromioclavicular arthritis, clinical and radiological findings indicating glenohumeral joint pathology, referred pain from the neck or internal organs, generalised muscular pain syndrome with bilateral muscular pain in the neck and shoulders, a history of inflammatory arthritis, diabetes mellitus type 1, previous fractures or surgery to the shoulder, or contraindications to local steroid injections or if they had received any corticosteroids the last month before inclusion. We also excluded patients with a shoulder pain and disability index score below 30 points, representing minor complaints that did not indicate corticosteroid injections.
The same medical doctor (OME) examined all patients referred to the clinic for eligibility. They were thoroughly informed about the study and signed an informed consent if they were willing to participate.
Study protocol
We scheduled patients who were eligible and willing to participate in the study for an appointment at the clinic for baseline registrations and treatment according to the protocol. We recorded magnetic resonance imaging results. Patients not able or unwilling to have magnetic resonance imaging had diagnostic ultrasonography. Patients had an equal probability of assignment to the two treatment groups. We used the computer program Clinstat to generate a predetermined randomisation sequence with a randomised variable block size of three, four, and five. A member of the study group who was not participating in patients eligibility, allocation to treatment, or outcome assessment developed the randomisation sequence. The consultant physician responsible for the injections held the only copy of the randomisation sequence. After the baseline registrations, we gave each participant a study number. To ensure concealed allocation, each patient was referred to the consultant physician responsible for injections, who then allocated the patient to one of the treatment groups according to the randomisation sequence. Patients and the outcome assessor were blinded for treatment assignment. The consultant physician preparing and administering the injections was not blinded.
Treatment
We allocated patients randomly to either local or systemic steroid injection. Both groups received injections of local anaesthetic in the shoulder and the gluteal region. We provided local anaesthetic to improve blinding of participants by inducing a temporary pain relief (impingement test) and mask possible post-injection pain. The "local" group received a sonographically guided injection of 2 ml (10 mg/ml) triamcinolone (Kenacort-T, Bristol-Myers Squibb) and 5 ml (10 mg/ml) lidocaine hydrochloride (Xylocaine, AstraZeneca) to the subacromial bursa and an intramuscular injection of 4 ml (10 mg/ml) lidocaine hydrochloride to the upper gluteal region. The "systemic" group received a sonographically guided injection of 5 ml (10 mg/ml) lidocaine hydrochloride to the subacromial bursa and an intramuscular injection of 2 ml (10 mg/ml) triamcinolone and 2 ml (10 mg/ml) lidocaine hydrochloride to the upper gluteal region.
The injection procedure was standardised. The same independent consultant physician responsible for the injections prepared syringes immediately before use. She gave the sonographically guided injection first, using commercial ultrasound equipment (Medison 128 BW prime, Medison Co, Seoul, Korea) with a 5-9 MHz linear transducer for guidance. Patients sat facing the ultrasound screen with the affected arm rotated internally behind the back, elbow bent, and the back of the hand resting against the lower back. The physician sterilised patients skin and the ultrasound transducer with alcohol and applied sterile gel to the transducer. She used the ultrasound probe to visualise the insertion of the supraspinatus tendon and the subacromial bursa on the longitudinal axis, taking care that the contents of the syringes were never shown to the participants. She used the anterior approach with a 0.8x50 mm intramuscular needle for the subacromial injections, perforating the skin and tracking the needle in real time until it reached the subacromial bursa. She emptied the content of the syringe into the subacromial bursa, taking care to avoid direct injection into the rotator cuff tendons. The physician then gave patients the intramuscular injection in the upper gluteal region. We allowed patients to use analgesics in the trial period, and to continue any physiotherapy programme that they were attending at baseline. We did not allow other additional treatment in the research period.
Outcome measures
Blind follow-up measures were carried out at two and six weeks after treatment. Baseline demographics and clinical characteristics included sex, age, duration of symptoms, sickness leave, workers compensation claims, dominant side affected, previous episodes of shoulder pain, and drug use. We used the Hopkins symptom checklist to measure emotional distress.20 We asked patients to report additional treatment at follow-ups. The main outcome measure was the shoulder pain and disability index.21 This is a self administered, validated, shoulder specific questionnaire consisting of five pain and eight disability items. Patients recorded responses on each item on visual analogue scales on the basis of the previous weeks symptoms. We calculated the score by summing and then averaging the two subscales to give a score out of 100. Secondary outcome measures were the Western Ontario rotator cuff index22; active range of abduction and flexion; the participants assessment of change in the main complaint compared with baseline, measured on an 18 point ordinal scale; and two separate questions about pain at rest and pain during activity measured on a nine point ordinal scale.23 Patients completed all questionnaires before the consultation and were assessed by the same physician (OME) blinded for treatment group. He measured active abduction and flexion with an electronic digital inclinometer (EDI 320, Cybex Inc, Ronkonkoma, NY) according to a standardised protocol.24
Statistical analysis
After a pilot study, we estimated the standard deviation of change in shoulder pain and disability index to be approximately 20 points. The minimal clinically important difference has been variously reported to be 10 points and 13.2 points.25 26 We designed this study to detect a clinically relevant difference of 10 points with 95% probability and 80% power. We needed a sample size of 63 patients per group for a two sided t test and 48 patients per group for the more efficient analysis of covariance.27 To account for a 10% rate of loss at follow-up and still meet these requirements, we included 106 patients in the study. We did not plan or do any interim analyses.
We analysed data according to the principle of intention to treat. All hypothesis tests were two tailed with a significance level of 5%. We calculated point estimates with associated 95% confidence intervals for mean differences in improvement between groups in shoulder pain and disability index score and Western Ontario rotator cuff index score. For analysis of participants change in main complaint, pain at rest, and pain during activity, we calculated non-parametric estimates with median, interquartile range, and median difference in improvement between groups with 95% confidence intervals. As recommended, we planned and used an analysis of covariance model with adjustment for baseline differences.28 We used the Mann-Whitney U test for hypothesis testing of group differences in main complaint. We used Minitab 15.1.1.0 [EC] and Confidence Interval Analysis 2.1.2 to calculate non-parametric statistics and SPSS 16.0 for Mac for all other statistical analyses. We reported the study according to the CONSORT rules.
|
|
|
Only five patients receiving local injections and three patients receiving systemic injections had a normal and pain-free range of abduction and negative clinical tests. Nine patients from both groups reported mild adverse effects such as facial redness, dizziness, and feeling of warmth. One patient in the local group and four patients in the systemic group reported post-injection pain in the shoulder. No serious side effects were reported.
Interpretation of results
We reported statistically significant, but clinically small, group differences for two secondary outcome measures. The observed inconsistency between outcome measures may be due to the effects of multiple testing, which increase the probability of positive results. With Bonferroni corrections, no results remained statistically significant. Conclusions of effectiveness of an intervention may be influenced by the choice of scoring system for rating patients.29 30 We cannot rule out the possibility that the Western Ontario rotator cuff index is a more sensitive outcome measure than the shoulder pain and disability index. Clinimetric studies investigating the responsiveness of the shoulder pain and disability index and the Western Ontario rotator cuff index with other shoulder questionnaires indicate that both outcome measures are responsive.31 32 The two scores may measure different constructs, however, as the shoulder pain and disability index is a pain and disability score and the Western Ontario rotator cuff index is a health related quality of life score. Consensus on a core set of outcome measures in shoulder interventions is warranted.
The most likely interpretation of our results is that local ultrasound guided corticosteroid injections do not improve patients outcomes compared with systemic corticosteroid injection in rotator cuff disease.
Comparison with existing literature
Previous randomised trials and systematic reviews have reported contradictory results on the effectiveness of corticosteroid injections for rotator cuff disease.9 11 Alvarez et al compared blind injection of betamethasone with Xylocaine in patients with chronic rotator cuff disease. They found a moderate improvement in symptoms in both groups but found no difference in improvement between groups.33 Considerable placebo effects have been seen with injection treatment, acupuncture, and extracorporeal shock wave therapy for shoulder disease.34 35 36 Thus, our results could be attributed to the systemic effect of corticosteroids, injections of lidocaine into the subacromial bursa, and placebo effects.
Naredo et al and Chen et al have reported better outcomes for pain, disability, and range of motion after ultrasound guided injections than blind subacromial injections.17 18 Thus, we cannot rule out the possibility that the use of ultrasound for better placement of lidocaine injections contributed to the results of our study. We used 20 mg of triamcinolone to parallel the dose used in the study by Naredo et al. Several previous studies have used higher doses of corticosteroid injections for rotator cuff disease. Limited evidence exists for better efficacy with higher corticosteroid dosage,10 but 20 mg of triamcinolone is generally regarded as a low dose for systemic treatment. A higher dosage would be likely to reduce the difference between groups and increase adverse effects.
Possible confounders and weaknesses
The effectiveness of corticosteroid injections might be influenced by the duration of rotator cuff disease. The favourable result of ultrasound guided corticosteroid injections in the study by Naredo et al occurred in a group of patients with a first flare of shoulder pain.18 Longstanding symptoms are a negative prognostic factor for clinical outcome.37 38 A large portion of patients in our study had had symptoms for more than six months, and many patients had recurring episodes of shoulder pain. No differences existed in duration of disease between groups in our study.
We based inclusion of patients on strict clinical criteria.23 This strategy is in accordance with Park et al, who found that the use of a combination of clinical tests increased the accuracy of clinical diagnosis.39 Our inclusion criteria are quite similar, but not identical, to the criteria used in the study by Park et al. By combining the Hawkins-Kennedy impingement sign, the painful arc sign, and the infraspinatus muscle strength test, they achieved a post-test probability of 95% for any degree of impingement syndrome. In our study, the clinical classification of soft tissue shoulder disorders and use of strict inclusion criteria lowered the external validity with respect to the 312 patients considered for inclusion.
Twenty patients in the local group and 18 patients in the systemic group had had previous shoulder injections. Eight patients in the local group and five in the systemic group had concurrent physiotherapy. Both previous and concurrent treatment might have influenced individual treatment response, but these possible confounders existed in the same number of patients in each intervention group. We did not register type of physiotherapy or use a structured reporting system for additional drug use such as the defined daily dose or the anatomical therapeutic chemical classification system that could have revealed a bias in compliance caused by these potential confounders.
A weakness in the design of the study was the lack of blinding of the physician who gave the injections. Even though we standardised the procedure and took care not to reveal group assignment, a bias may have been introduced. If present, we believe the bias was most likely to be in favour of the local group on the basis of the good results of recent studies using ultrasound guided corticosteroid injections and the fact that the physician responsible for giving injections had specialised in diagnostic ultrasonography and ultrasound guided injections.
We set the period of time between treatment and follow-up testing to optimise the anticipated pharmacological effect of the injected steroid. Evidence of the effectiveness of long term treatment is scant.40 Recent studies have reported better short term and inferior long term results from corticosteroid intervention than from physiotherapy and no intervention (controls).41 42
The modest improvements in self reported complaints and range of motion after steroid injection seen in this and previous studies suggest that steroid injection is not a sufficient treatment strategy for patients with rotator cuff disease. Better outcome in terms of range of motion is reported after attendance at an active physiotherapy programme.7 8 43
Conclusion
The results of this study do not indicate that local corticosteroid injection is more effective than systemic corticosteroid injection for short term improvement in rotator cuff disease. Ultrasound guided injection of lidocaine into the subacromial bursa might have contributed to the observed improvement in both groups.
|
Cite this as: BMJ 2009;338:a3112
Contributors: All authors participated in the planning of the study and contributed to the protocol. SK was responsible for the injection treatment. OME analysed the data and drafted the manuscript, which were revised by the other authors. All authors approved the final version. OME is the guarantor.
Funding: The University of Oslo funded this study.
Competing interests: None declared.
Ethical approval: The regional ethics committee approved this study. Included patients gave written informed consent.
Provenance and peer review: Not commissioned; externally peer reviewed.
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
StumbleUpon
Technorati What's this?
Read all Rapid Responses