Jump to: Page Content, Site Navigation, Site Search,
You are seeing this message because your web browser does not support basic web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.
Steve Halligan a Intestinal
Imaging Centre, St Mark's Hospital, Harrow HA1 3UJ, b Department of
Radiology, Mater Misericordiae Hospital, Dublin, Republic of Ireland
Correspondence to: S Halligan s.halligan{at}ic.ac.uk
Virtual colonoscopy is a new procedure that fuses computed
tomography of the large bowel with advanced techniques for rendering three dimensional images to produce views of the colonic mucosa similar
to those obtained during "real" colonoscopy. Preliminary results
suggest that it surpasses barium enema and approaches the sensitivity
of conventional colonoscopy. This review summarises the technical
developments that have made virtual colonoscopy possible and describes
the expected advantages of this exciting technique over conventional
endoscopy and more traditional imaging methods. We describe its
possible applications and outline further technical developments that
can be expected in the near future.
In 1994 the Royal Mail issued a series of four stamps celebrating
major medical advances of the 20th century; three of these were
radiological (ultrasound scanning, computed tomography, and magnetic
resonance imaging). Radiology is a technology based discipline and is
one of the most rapidly developing medical specialties, not least
because advances in computer technology are almost instantly incorporated into the various imaging modalities. Image acquisition and
display are constantly improving, and image processing that required
until recently a dedicated workstation is now possible with a personal
computer. The possibilities for diagnostic imaging that are available
today would have been unimaginable only 30 years ago, and computed
tomography has played a central role in this
development.
Invented by Godfrey Hounsfield in 1973,1 computed
tomography involves rotating an x ray tube around a subject,
the tube taking one dimensional views as it travels. These individual
projections are digitally summated and reconstructed by means of
mathematical algorithms to give a two dimensional "slice" through
the body. Until recently, mechanical constraints limited tube rotation
to 360°: a slice was taken, and the x ray tube would
return to its original position while the table supporting the subject
moved to the next acquisition position, after which the whole process started again (fig 1a). This process, known as dynamic incremental computed tomography, meant that studies comprised a series of consecutive slices of variable thickness and separation, and they were
also relatively time consuming.
![]()
Background
Top
Background
Conventional and spiral...
Bowel imaging and computed...
Virtual colonoscopy
Preliminary results
Colorectal cancer screening
Future developments
References
Predicted developments
New multi-slice spiral computed tomography will increase the
sensitivity of virtual colonoscopy for detecting colorectal polyps
Faster and cheaper computer power will translate into faster and more
complex image reconstruction, such as "virtual pathology"
Image analysis and polyp detection are likely to become automated
Oral labelling agents will eliminate the need for bowel cleansing
Magnetic resonance imaging will be increasingly used for virtual
examinations
Because virtual colonoscopy is safe, easy, complete, and, once bowel
cleansing is eliminated, non-invasive, it will assume a prominent role
in screening for colorectal cancer
![]()
Conventional and spiral computed tomography
Top
Background
Conventional and spiral...
Bowel imaging and computed...
Virtual colonoscopy
Preliminary results
Colorectal cancer screening
Future developments
References

View larger version (22K):
[in a new window]
Fig 1.
Conventional computed tomography comprises a
series of incremental 360° degree slices through the subject (a),
whereas in spiral computed tomography the x ray tube
continuously rotates around the subject, who passes through the scanner
in a continuous movement (b)
The introduction of complex slip ring technology has made it
possible to continuously rotate the x ray tube during
image acquisition, and higher tube loading has also enabled prolonged
exposure. It seems sensible to combine these developments with
continuous table movement rather than time consuming, stepped
increments, so that a subject can be examined in one, rapid
sequence.2 Because the tube is continuously rotating while
the subject moves smoothly through the scanner, the x
ray beam describes a spiral pathway through the body (fig 1b)
hence
the term spiral computed tomography.
There are several advantages with spiral computed tomography.
Obviously it is faster, so that an entire study can be completed in a
single breath-hold. This has eliminated misregistration artefacts, which were previously caused by uneven inspiration between individual slices. The reduced scanning time also means that, when intravenous iodine compounds are needed to enhance the contrast of some organs, the
entire body part being studied can now be imaged at peak contrast. Most
importantly, whereas the images produced by conventional computed
tomography are slices through the patient, mirroring exactly how they
are acquired, data acquisition during spiral computed tomography is
continuous in three dimensions and therefore volumetric. Although
images are conventionally presented as single slices for convenience,
it should be borne in mind that these are two dimensional
reconstructions from a truly three dimensional dataset.
| |
Bowel imaging and computed tomography |
|---|
|
|
|---|
These technical developments have been paralleled by changing attitudes towards luminal bowel imaging with computed tomography. It was initially thought that computed tomography of the abdomen and pelvis was best suited to solid organs, and the bowel was simply labelled with orally or rectally applied contrast medium so that it could be easily identified and distinguished from any disease. However, the concept of using computed tomography as the primary tool for colonic investigation was precipitated by investigators searching for an alternative to the barium enema in radiological investigations of frail, elderly patients.3
|
Indeed, it soon became apparent that the colon could be
visualised in exquisite detail with spiral computed tomography if the
principles underlying barium radiology were similarly applied
namely, distension of the colon, adequate tissue contrast, and temporary paralysis by means of intravenous smooth muscle relaxants
a procedure that has been termed "spiral CT pneumocolon."4
Patients undergo full bowel preparation, an intravenous smooth muscle
relaxant is administered, and the colon then insufflated with room air until fully distended. Once satisfactory distension has been achieved, spiral computed tomography is performed to encompass the entire colon,
possibly with simultaneous intravenous injection of contrast medium.
This approach allows detection of small polyps (fig 2), unlike
examination without preparation, which is used to detect large cancers
in frail elderly patients.
| |
Virtual colonoscopy |
|---|
|
|
|---|
The combination of fast volumetric imaging, the application of barium techniques to computed tomography, and formidable developments in rendering three dimensional images by computer graphics packages has enabled virtual colonoscopy (computed tomography colography). First described by Vining and coworkers in 1994,5 virtual colonoscopy applies techniques for rendering complex images to spiral CT pneumocolon. The considerable difference in image contrast between intraluminal gas and the surrounding colonic wall and soft tissues makes this interface an easy target for the rendering of three dimensional images, allowing creation of a graphical representation of the colon through which the viewer can "navigate" (fig 3).
|
A spiral CT pneumocolon of a patient lying supine is performed in a single acquisition, with the patient holding a breath for the first 15-20 seconds (covering the upper abdomen) while the rest can be acquired during gentle respiration. The study is generally repeated with the patient lying prone to ensure that all colonic segments have been imaged distended. Reconstruction parameters vary but in a typical study would be at 2 mm intervals, with a 3 mm overlap of slices. The data are then downloaded to an independent workstation equipped with appropriate software for rendering perspective and volume. The computer generates a retrograde intraluminal "fly through" navigation from rectum to caecum and repeats it in the opposite direction.
Both antegrade and retrograde virtual colonoscopies are stored in
a "cine loop" format and can be viewed directly from the workstation monitor. Image analysis is interactive, and the radiologist can choose to view the rendered mucosa from any angle, pass through the
tightest stricture, and even cross the colonic wall into adjacent structures. Virtual studies are usually examined in combination with
the standard axial computed tomograms. The computer can also generate
two dimensional images at cross sectional and orthogonal angles to the
long axis of the colon to aid interpretation.
| |
Preliminary results |
|---|
|
|
|---|
Preliminary results indicate that the accuracy of virtual colonoscopy for detecting colon polyps may exceed that of barium enema examination and approach that of conventional colonoscopy. In a study of 70 consecutive patients known to have polyps or being followed up one to five years after polypectomy the sensitivity and specificity of virtual colonoscopy were 75% and 90% respectively for adenomatous polyps >10 mm in diameter, 66% and 63% for adenomas >5 mm, and 45% and 80% for polyps <5 mm.6 Comparison with single contrast barium enema examination, still widely practised in the United States, suggests that virtual colonoscopy has a higher detection rate with fewer false positive results.7 At the time of writing, no study has compared virtual colonoscopy with double contrast barium enema examination. In studies of asymptomatic patients with no prior neoplasia virtual colonoscopy had a sensitivity of 75% for adenomas >10 mm in diameter,8 and other studies have reported sensitivities of between 91% and 100% for polyps >10 mm 9 10 and sensitivity approaching 100% for carcinomas.11
Conventional colonoscopy is a difficult and technically demanding
procedure, and is frequently incomplete for these reasons. A major
attraction of virtual colonoscopy is the greater certainty of a
complete examination, even when a carcinoma precludes proximal passage
of a real colonoscope: computed tomography of 29 patients with
occlusive cancers in whom colonoscopy and barium enema had failed to
pass the stricture found all known tumours and revealed two further
cancers and 24 polyps proximal to the site of
obstruction.12 Furthermore, localisation of lesions is
likely to be more accurate with computed tomography: in one study 38 cancers were correctly localised by means of computed tomography
compared with 32 by conventional colonoscopy.13
| |
Colorectal cancer screening |
|---|
|
|
|---|
Almost simultaneous with the birth of virtual colonoscopy were
suggestions that it could be used for screening for colorectal cancer,
and there are several arguments in its favour. Virtual colonoscopy
seems able to reliably detect adenomatous polyps, the precursor of
cancer, with high accuracy. Furthermore, the entire colon is easily
examined, in contrast to colonoscopy. It is quicker and less
technically demanding than either colonoscopy or even barium enema
examination. It is safe, although there is a theoretical risk from
radiation exposure, roughly equal to that from barium enema radiography
(higher if both supine and prone studies are performed). Other organs
are also imaged and could be screened simultaneously. The skills needed
to interpret virtual studies are different from those required for
barium radiology and might be less demanding because of the wealth of
imaging information provided. Lastly, virtual colonoscopy is perceived
as a new and exciting development by radiologists, and this enthusiasm
may help staff recruitment to any future screening programme.
| |
Future developments |
|---|
|
|
|---|
Virtual colonoscopy is in the early stages of its development. Its feasibility has clearly been demonstrated, and larger, multicentre studies are needed to determine its sensitivity and specificity outside specialist units. Multiple technical parameters can be altered during image acquisition, and a coherent technique has yet to emerge. Multi-slice spiral computed tomography has just been introduced and will reduce examination time even further. Furthermore, the principles underlying virtual colonoscopy by spiral computed tomography can be just as easily applied to magnetic resonance imaging, which carries no radiation penalty.14
Presently, most limitations apply to the processing and analysis of
images after their acquisition
analysis of a single study takes about
30-60 minutes. However, the current constraints imposed by available
processing power and digital storage are likely to diminish. Also, it
seems that diagnosis can usually be made from the two dimensional
images, and generating a three dimensional image, the most demanding
application in terms of computer power, may be necessary only for
problem solving, such as differentiating between a polyp and a haustral
fold.15
Other rendering techniques are also being developed. It is possible to generate three dimensional images that resemble conventional fluoroscopic double contrast enema studies or to artificially straighten the colon, open it, and view the rendered, flattened surface en face, imitating the pathologist's view. Navigation software is also progressing; luminal "fly through" navigation can be automated and collision avoidance techniques used, with simultaneous antegrade and retrograde viewing.
At present, full colonic cleansing is mandatory for an acceptable examination, but workers are already investigating the possibility of using oral contrast medium with a view to tagging faecal residue so that it can be differentiated from pathological features and possibly digitally excluded from the image. Furthermore, because virtual colonoscopy generates images of the colonic wall, it is possible to apply algorithms that automatically detect and label regions where it is thickened, alerting the radiologist to the possible presence of polyps. Perhaps flat adenomas can be detected this way.
The development and refinement of all of these techniques are likely to
have tremendous impact on the speed and accuracy of virtual colonoscopy
and its interpretation in the near future. The performance
characteristics of virtual colonoscopy are certain to improve with
improvements in hardware and software innovation and radiologists'
experience. With regard to its potential as a screening tool, its
performance in real populations and its cost, patient acceptability,
and availability will need to be determined.
| |
Footnotes |
|---|
Competing interests: None declared.
| |
References |
|---|
|
|
|---|
| 1. | Hounsfield GN. Computerized transverse axial scanning (tomography): Part 1. Description of the system. Br J Radiol 1973; 46: 1016-1022[Medline]. |
| 2. |
Kalender WA, Seissler W, Klotz E, Vock P.
Spiral volumetric CT with single breath-hold technique, continuous transport and continuous scanner rotation.
Radiology
1990;
176:
181-183 |
| 3. | Fink M, Freeman AH, Dixon AK, Coni NK. Computed tomography of the colon in elderly people. BMJ 1994; 308: 101. |
| 4. | Amin Z, Poulos PB, Lees WR. Spiral CT pneumocolon for suspected colonic neoplasms. Clin Radiol 1996; 51: 56-61[Medline]. |
| 5. | Vining DJ, Gelfand DW, Bechtold RE, Scharding ES, Grishaw EK, Shifrin RY, et al. Technical feasibility of colon imaging with helical CT and virtual reality [abstract]. AJR Am J Roentgenol 1994; 162(S): 104. |
| 6. |
Hara AK, Johnson CD, Reed JE, Ahlquist DA, Nelson H, MacCarty RL, et al.
Detection of colorectal polyps with CT colography: initial assessment of sensitivity and specificity.
Radiology
1997;
205:
59-65 |
| 7. | Hara AK, Johnson CD, Reed JE, Ahlquist DA, Nelson H, Harmsen WS, et al. Computed tomographic colography for polyp detection: early comparison against barium enema. Gastroenterology 1997; 112: A575. |
| 8. | Rex DK, Vining D, Kopecky K. Screening for polyps using spiral CT with and without virtual colonoscopy [abstract]. Gastrointest Endosc 1997; 45: AB116. |
| 9. |
Kay CL, Kulling D, Evandelou H, Hawes RH, Young JW, Cotton PB.
CT-based virtual colonoscopy correlation with colonoscopy in the detection of space-occupying lesions of the colon [abstract].
Radiology
1997;
205:
195.
|
| 10. |
Dachman AH, Kuniyoshi JK, Boyle CM, Samara Y, Hoffmann KR, Rubin DT, et al.
CT colonography with three-dimensional problem solving for detection of colonic polyps.
AJR Am J Roentgenol
1998;
171:
989-995 |
| 11. |
Royster AP, Fenlon HM, Clarke PD, Nunes DP, Ferrucci JT.
CT colonoscopy of colorectal neoplasms: two-dimensional and three-dimensional virtual reality techniques with colonoscopic correlation.
AJR Am J Roentgenol
1997;
169:
1237-1242 |
| 12. |
Fenlon HM, McAneny DB, Nunes DP, Clarke PD, Ferrucci JT.
Occlusive colon carcinoma: virtual colonoscopy in the preoperative evaluation of the proximal colon.
Radiology
1999;
210:
423-428 |
| 13. |
Fenlon HM, Nunes DP, Clarke PD, Ferrucci JT.
Colorectal neoplasm detection using virtual colonoscopy: a feasibility study.
Gut
1998;
43:
806-811 |
| 14. |
Lubolt W, Steiner P, Bauerfeind P, Pelkonen P, Debatin JF.
Detection of mass lesions with MR colonography: preliminary report.
Radiology
1998;
207:
59-65 |
| 15. |
Fenlon HM, Ferrucci JT.
Virtual colonoscopy. What will the issues be?
AJR Am J Roentgenol
1997;
169:
453-458 |
Read all Rapid Responses
Israeli students are refusing to perform intimate examinations on anaesthetised women without their informed consent.