Br Med J 1978;1:1018-1020 (22 April), doi:10.1136/bmj.1.6119.1018
Creamatocrit: simple clinical technique for estimating fat concentration and energy value of human milk.
A Lucas,
J A Gibbs,
R L Lyster,
J D Baum
A simple micromethod has been devised for estimating the fat
and energy content of human milk based on the centrifugation
of milk in a haematocrit centrifuge. The percentage of cream,
or "creamatocrit," is read from the haematocrit capillary tube
and is linearly related to the fat and energy content. The technique,
which is rapid and cheap, may be used in clinical practice,
in research, and in epidemiological studies.

CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
StumbleUpon
Technorati What's this?
This article has been cited by other articles:
-
Fewtrell, M S, Loh, K L, Blake, A, Ridout, D A, Hawdon, J
(2006). Randomised, double blind trial of oxytocin nasal spray in mothers expressing breast milk for preterm infants. Arch. Dis. Child. Fetal Neonatal Ed.
91: F169-F174
[Abstract]
[Full text]
-
Lubetzky, R., Littner, Y., Mimouni, F. B., Dollberg, S., Mandel, D.
(2006). Circadian variations in fat content of expressed breast milk from mothers of preterm infants.. J. Am. Coll. Nutr.
25: 151-154
[Abstract]
[Full text]
-
Hartmann, S. U., Wigdahl, B., Neely, E. B., Berlin, C. M., Schengrund, C.-L., Lin, H.-M., Howett, M. K.
(2006). Biochemical Analysis of Human Milk Treated With Sodium Dodecyl Sulfate, an Alkyl Sulfate Microbicide That Inactivates Human Immunodeficiency Virus Type 1. J Hum Lact
22: 61-74
[Abstract]
-
Mandel, D., Lubetzky, R., Dollberg, S., Barak, S., Mimouni, F. B.
(2005). Fat and Energy Contents of Expressed Human Breast Milk in Prolonged Lactation. Pediatrics
116: e432-e435
[Abstract]
[Full text]
-
Ogg, S. L., Weldon, A. K., Dobbie, L., Smith, A. J. H., Mather, I. H.
(2004). Expression of butyrophilin (Btn1a1) in lactating mammary gland is essential for the regulated secretion of milk-lipid droplets. Proc. Natl. Acad. Sci. USA
101: 10084-10089
[Abstract]
[Full text]
-
Kent, J. C., Ramsay, D. T., Doherty, D., Larsson, M., Hartmann, P. E.
(2003). Response of Breasts to Different Stimulation Patterns of an Electric Breast Pump. J Hum Lact
19: 179-186
[Abstract]
-
Slusher, T., Hampton, R., Bode-Thomas, F., Pam, S., Akor, F., Meier, P.
(2003). Promoting the Exclusive Feeding of Own Mother's Milk through the Use of Hindmilk and Increased Maternal Milk Volume for Hospitalized, Low Birth Weight Infants (< 1800 grams) in Nigeria: A Feasibility Study. J Hum Lact
19: 191-198
[Abstract]
-
Fewtrell, M., Lucas, P., Collier, S., Lucas, A.
(2001). Randomized Study Comparing the Efficacy of a Novel Manual Breast Pump With a Mini-Electric Breast Pump in Mothers of Term Infants. J Hum Lact
17: 126-131
[Abstract]
-
Wohlberg, L. K., Geary, B. F.
(1994). Team Approach to Breastfeeding the ELBW Infant: A Case Report. J Hum Lact
10: 181-183
[Abstract]